 Return to top of page · Post #: 31 · Written at 7:45:47 PM on 17 February 2019.
Brad's avatar
 Administrator
 Location: Naremburn, NSW
 Member since 15 November 2005
 Member #: 1
 Postcount: 7306

Hydrogen peroxide is used to sterilise many surgical instruments that cannot be sterilised using steam. One such system is made by Sterrad.


‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾
A valve a day keeps the transistor away...

 
 Return to top of page · Post #: 32 · Written at 6:12:17 AM on 18 February 2019.
STC830's Gravatar
 Location: NSW
 Member since 10 June 2010
 Member #: 681
 Postcount: 1256

This was a Dalek sized thing on wheels, put in the centre of the ward. Room evacuated, all doors and air conditioner vents taped or otherwise sealed up.
In pure form hydrogen peroxide is extremely reactive. So it can hardly be pure and must be diluted with water. So plenty of water flying around as well .


 
 Return to top of page · Post #: 33 · Written at 10:41:34 AM on 18 February 2019.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5257

Hydrogen Peroxide (Rocker fuel) is not particularly stable, as the Germans found out in WWII. Its decomposition is violent & exothermic. It does not need much contamination to cause that to happen.


 
 Return to top of page · Post #: 34 · Written at 1:55:58 PM on 18 February 2019.
GTC's avatar
 GTC
 Location: Sydney, NSW
 Member since 28 January 2011
 Member #: 823
 Postcount: 6687

 
 Return to top of page · Post #: 35 · Written at 4:54:48 PM on 18 February 2019.
STC830's Gravatar
 Location: NSW
 Member since 10 June 2010
 Member #: 681
 Postcount: 1256

Yes something like that.


 
 Return to top of page · Post #: 36 · Written at 3:06:47 PM on 3 March 2019.
Skymaster's Gravatar
 Location: Lalor Park, NSW
 Member since 7 April 2018
 Member #: 2237
 Postcount: 57

It gets more fun now with AS3000:2018 mandating RCD's on all domestic subcircuits ....period.
So your hot water, ovens, and everything else all now need to be covered, not just General Power & Light circuits.

Fortunately the majority of installs are done with RCBO's, so the 1 or 2 RCDs for the house should disappear, and it's just a single circuit that trips out.


 
 Return to top of page · Post #: 37 · Written at 11:25:20 AM on 14 March 2019.
Labrat's avatar
 Location: Penrith, NSW
 Member since 7 April 2012
 Member #: 1128
 Postcount: 374

I would bet that the corroded lead on the filter cap, was the positive lead.
I never saw a negative lead corrode.

Wayne.


 
 Return to top of page · Post #: 38 · Written at 5:05:45 PM on 14 March 2019.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5257

Positive is normally the hot lead. It is normally the one that gives the most trouble. It is noted an all of my vehicles from the fifties even the Grey Fergie, that they were positive earth & normally used open braided leads for the earth straps. Those leads would dissipate quite a bit of heat.

LV garden solenoids reduce their corrosion by using AC.


 