Hi Guys,
Had a search around (Internet and the forum) but haven't managed to find any wire that I am happy to use inside the chassis of the radiogram I am repairing. I need red and yellow to replace the perished internal wiring on the valve chassis. I assume 300V 105 degrees is needed and something like 16AWG?
Does anybody know of a source without having to buy 100M of the stuff?

Thanks,
Glenn.


 
 Return to top of page · Post #: 2 · Written at 4:24:08 PM on 29 November 2015.
Steve's Gravatar
 Location: Donald, VIC
 Member since 7 January 2006
 Member #: 13
 Postcount: 265

I have the wire you need Glenn iam out of stock but will have more soon


‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾
Steve.

 
 Return to top of page · Post #: 3 · Written at 4:30:15 PM on 29 November 2015.
GTC's avatar
 GTC
 Location: Sydney, NSW
 Member since 28 January 2011
 Member #: 823
 Postcount: 6687

Evatco has 8 colours Glenn:

http://www.evatco.com.au/product-list/wire/wire-cloth-covered-single-core-2/

Sold by the metre and fast order turnaround in my experience.


 
 Return to top of page · Post #: 4 · Written at 10:19:27 PM on 29 November 2015.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5254

Whilst most wire will stand more than its rated voltage. Valve radios with filament rectifiers & Solid state rectifiers that produce voltage before the heater valves start to conduct, can get to 500VDC

From memory EVATCO's cloth type stuff was 600V. should be on the site. Assume Steve's is similar?

Also consider that when replacing Electrolytics on the "B" rail.

Accuracy of advice depends on what you tell us.

Marc


 
 Return to top of page · Post #: 5 · Written at 11:39:44 PM on 29 November 2015.
GTC's avatar
 GTC
 Location: Sydney, NSW
 Member since 28 January 2011
 Member #: 823
 Postcount: 6687

From memory EVATCO's cloth type stuff was 600V.

Yes, it is.

should be on the site

It is, simply follow the link I posted.


 
 Return to top of page · Post #: 6 · Written at 12:13:18 AM on 30 November 2015.
Steve's Gravatar
 Location: Donald, VIC
 Member since 7 January 2006
 Member #: 13
 Postcount: 265

Evatcos is same ( they got theirs from me originally ) I don't keep much anymore of the restoration lines, unless the orders are world beaters in volume. Its not really worth my while you know !

A new knob il have in soon, very very rare and il have several 100 of those.


‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾‾
Steve.

 
 Return to top of page · Post #: 7 · Written at 1:01:10 AM on 30 November 2015.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5254

Think we have this under control even that we have no idea what it is? I will probably need a cap re-stock soon.

How things have changed with caps. I have a Grigsby-Grunow (1932) on the bench & that has two 8μF filters (Non Polarised) 100 x 30 x 50mm. The last set (1929) similar had a 50 OP valve & that had over 300V on the plate (max 450V with -84v on the grid (separate rectifier on its own winding) needed to watch the fingers with that one.

Marc


 
 Return to top of page · Post #: 8 · Written at 1:13:22 PM on 30 November 2015.
Trackhappy's Gravatar
 Location: Brisbane, QLD
 Member since 12 November 2015
 Member #: 1824
 Postcount: 20

Sorry Marc, the details of the unit are in a separate Newbie thread, I should have added it in here. Mullard MAS1153. Original wires are multi-strand rubber coated. Replacing all caps except Mica, plus power cord and a broken dial string, and now internal wiring. The evatco link listed is a single strand, but there is multi-strand on their site.

Steve has kindly responded, but he is out of stock and my tiny order isn't enough to get him out of retirement... (joke ).


 
 Return to top of page · Post #: 9 · Written at 8:40:37 PM on 30 November 2015.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5254

I have used EVATCO wire. You can actually buy the plug & cable (suicide cable) as one piece & thats actually cheaper if your not fussy & I will often recycle a scrapped IEC cable from a computer that has been tossed.

Just cut the IEC plug off & you have a good cable with a moulded plug. I tend to use glands for the mains wire. Most times it can be put in pointy end inside the pan & that stops the cable twisting.

For general running around buy stranded in more than one colour. To make life easier I normally use Orange on DC before the B+ choke red for the direct B+ after the choke & blue on the RF screens. That makes it easier to follow.

A bit of circuit board lacquer, or shrink tube (band) stops it fraying at the ends.


 
 Return to top of page · Post #: 10 · Written at 9:59:27 PM on 30 November 2015.
GTC's avatar
 GTC
 Location: Sydney, NSW
 Member since 28 January 2011
 Member #: 823
 Postcount: 6687

The evatco link listed is a single strand, but there is multi-strand on their site.

http://www.evatco.com.au/product-list/wire/wire-cloth-covered-single-core/


 