Thanks to Ian, the set is now all standard.

I tested the incoming 1M5 first by plugging it into the IF socket and it worked as well as the 1M5 in that position.
Then I pulled the temporary 6U7 in the RF socket, put the original heater wiring back with the new 1M5.

The set then worked normally.

Job done.
Fred.


 
 Return to top of page · Post #: 17 · Written at 8:49:38 PM on 9 April 2023.
Marcc's avatar
 Location: Wangaratta, VIC
 Member since 21 February 2009
 Member #: 438
 Postcount: 5389

Obscure: I have two "Vesta" Ignition coil testers, both with restored innards, but one has a smashed meter & no external paper work. Only circuit is one from reverse engineering. 6V vibrator.

VCT Valve and circuit tester is mains, or 6V Vibrator.

Marc


 